Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the image-sizes domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the uael domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra-addon domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114
SY-0399095E SY-0303451D+SY-0303460E FOXBORO - Changxin Automation

SY-0399095E SY-0303451D+SY-0303460E FOXBORO

SY-0399095E SY-0303451D+SY-0303460E FOXBORO

The SY-0399095E is a FOXBORO transmitter that is used for measuring pressure.It is equipped with a remote seal,which makes it suitable for use in applications where the process medium is corrosive,viscous,or contains suspended solids.The transmitter has a 4-20mA output signal and can be configured using HART or FOUNDATION Fieldbus protocols.

Parameters

Pressure range:0-100 psi

Accuracy:+/-0.075%of calibrated span

Output signal:4-20mA

Power supply:10.5-42 VDC

Process connection:1/2″NPT

SY-0399095E SY-0303451D+SY-0303460E FOXBORO

This document provides information on the SY-0399095E, SY-0303451D, and SY-0303460E FOXBORO products, including their content and parameters.

SY-0399095E

Content

The SY-0399095E is a FOXBORO transmitter that is used for measuring pressure. It is equipped with a remote seal, which makes it suitable for use in applications where the process medium is corrosive, viscous, or contains suspended solids. The transmitter has a 4-20mA output signal and can be configured using HART or FOUNDATION Fieldbus protocols.

Parameters

  • Pressure range: 0-100 psi
  • Accuracy: +/- 0.075% of calibrated span
  • Output signal: 4-20mA
  • Power supply: 10.5-42 VDC
  • Process connection: 1/2″ NPT

SY-0399095E SY-0303451D+SY-0303460E  FOXBORO

SY-0303451D

Content

The SY-0303451D is a FOXBORO vortex flowmeter that is used for measuring the flow rate of liquids, gases, and steam. It has no moving parts and is therefore suitable for use in applications where the process medium contains suspended solids or debris. The flowmeter has a 4-20mA output signal and can be configured using HART or FOUNDATION Fieldbus protocols.

Parameters

  • Flow range: 0-300 m3/h (liquid), 0-3000 m3/h (gas/steam)
  • Accuracy: +/- 0.75% of reading
  • Output signal: 4-20mA
  • Power supply: 10.5-42 VDC
  • Process connection: Flanged

SY-0399095E SY-0303451D+SY-0303460E  FOXBORO1

SY-0303460E

Content

The SY-0303460E is a FOXBORO temperature transmitter that is used for measuring the temperature of liquids and gases. It has a thermocouple or RTD input and a 4-20mA output signal. The transmitter can be configured using HART or FOUNDATION Fieldbus protocols.

Parameters

  • Temperature range: -200 to 1800°C
  • Accuracy: +/- 0.2% of calibrated span
  • Output signal: 4-20mA
  • Power supply: 10.5-42 VDC
  • Process connection: 1/2″ NPT

SY-0399095E SY-0303451D+SY-0303460E  FOXBORO2