Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the image-sizes domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the uael domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra-addon domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114
MVAX31C1DF0754A ALSTOM - Changxin Automation

MVAX31C1DF0754A ALSTOM

MVAX31C1DF0754A ALSTOM

The ALSTOM MVAX31C1DF0754A circuit breaker has the following parameters:

Rated voltage:7.2kV

Rated frequency:50/60Hz

Rated current:800A

Short-circuit breaking capacity:25kA

Operating sequence:O-0.3s-CO-180s-CO

Insulation level:20/60/95kV BIL

Power frequency withstand voltage:32/70/125kV

Lightning impulse withstand voltage:60/125/200kV

Mechanical endurance:10,000 operations

Electrical endurance:1,000 operations

MVAX31C1DF0754A ALSTOM

In this document, we will provide you with all the necessary information regarding the ALSTOM MVAX31C1DF0754A product. This product is a high-performance circuit breaker designed to protect electrical networks from overloads and short circuits.

Product Information Content

The ALSTOM MVAX31C1DF0754A is a three-pole circuit breaker that operates on a voltage of 7.2kV. It has a rated current of 800A and a short-circuit breaking capacity of 25kA. The product’s design is compact and allows for easy installation in both indoor and outdoor environments. The circuit breaker is equipped with a trip-free mechanism that ensures the breaker cannot be held in the closed position when a fault occurs.

The product comes with the following accessories:

  • Terminal covers
  • Auxiliary contacts
  • Shunt trip
  • Under voltage release
  • Closing and opening coils
  • Mechanical interlocks

MVAX31C1DF0754A  ALSTOM

Parameters

The ALSTOM MVAX31C1DF0754A circuit breaker has the following parameters:

  • Rated voltage: 7.2kV
  • Rated frequency: 50/60Hz
  • Rated current: 800A
  • Short-circuit breaking capacity: 25kA
  • Operating sequence: O-0.3s-CO-180s-CO
  • Insulation level: 20/60/95kV BIL
  • Power frequency withstand voltage: 32/70/125kV
  • Lightning impulse withstand voltage: 60/125/200kV
  • Mechanical endurance: 10,000 operations
  • Electrical endurance: 1,000 operations

We hope this information is helpful in understanding the ALSTOM MVAX31C1DF0754A circuit breaker. If you have any further questions or require additional information, please do not hesitate to contact us.

MVAX31C1DF0754A  ALSTOM1

Conclusion

The ALSTOM MVAX31C1DF0754A is a reliable and efficient circuit breaker suitable for use in a wide range of medium-voltage power distribution systems. With its high breaking capacity, compact design, and compliance with international standards, it offers an excellent solution for your power distribution needs.