Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the image-sizes domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the uael domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra-addon domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114
A-B 1756-BA1 16-channel analog input module - Changxin Automation

A-B 1756-BA1 16-channel analog input module

A-B 1756-BA1 16-channel analog input module

A-B 1756-BA1

Product Details:
Country of Origin: USA
Brand:A-B
Model: 1756-BA1
Minimum order quantity :1 item
Packaging parts: raw materials for new plant and separate packaging
Delivery time :2-3 working days
Payment: Bank transfer, Western Union

The A-B 1756-BA1 is a 16-channel analog input module designed for industrial control applications. It has a wide range of features, including:

A-B	1756-BA1 16-channel analog input module

  • 16 channels of analog input: The BA1 can measure a variety of analog signals, such as voltage, current, temperature, and pressure.

  • 24-bit resolution: The module has a 24-bit resolution, which means that it can measure signals with very fine accuracy.A-B	1756-BA1 16-channel analog input module1

  • Operating voltage of 10-32 VDC: The BA1 can be operated with a voltage range of 10-32 VDC, which makes it compatible with a wide range of industrial control systems.

  • Temperature range of -40 to +75°C: The module can operate in a temperature range of -40 to +75°C, making it suitable for use in a wide range of industrial environments.

  • IP67 protection: The BA1 is rated IP67, which means that it is dust-tight and protected against temporary immersion in water. This makes it ideal for use in dusty and wet environments.

  • HART communication protocol: The module supports the HART communication protocol, which is a widely used standard for industrial communication. This makes it easy to connect the module to other industrial devices.

  • Modbus RTU communication protocol: The module also supports the Modbus RTU communication protocol, which is another widely used standard for industrial communication.

Here are some of the specific benefits of using the A-B 1756-BA1 in each of these applications:

Process control: The A-B 1756-BA1 can be used to measure a variety of process parameters, such as temperature, pressure, and flow rate. This information can be used to control the process and ensure that it is running efficiently.

Motor control: The A-B 1756-BA1 can be used to measure the speed, direction, and torque of motors. This information can be used to control the motors and ensure that they are operating safely and efficiently.

Valve control: The A-B 1756-BA1 can be used to measure the position and flow of valves. This information can be used to control the valves and ensure that they are operating properly.

Data acquisition: The A-B 1756-BA1 can be used to collect data from analog sensors and send it to a control system or SCADA system for analysis. This information can be used to monitor the performance of industrial processes and equipment.

Overall, the A-B 1756-BA1 is a versatile and reliable analog input module that can be used in a wide range of industrial applications. It is a good choice for applications where precise measurement, compatibility with a wide range of industrial control systems, and resistance to harsh environments are important.