Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the image-sizes domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the uael domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra-addon domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114
A-B 1734-OW4 Digital output module - Changxin Automation

A-B 1734-OW4 Digital output module

A-B 1734-OW4 Digital output module

A-B 1734-OW4

Today’s recommended products:
NVIDIA H100 PCIE
NVIDIA H800 PCIE
LAM 839-101612-885
LAM 839-101612-887
LAM 719-101612-885
LAM 719-101612-887
Many in stock, first come first served, first-hand source, channel
Contact: Han Fangting Sales Manager
Mobile :18030042035
QQ: 748141623
Email: 748141623@qq.com
Web site :www.changxindcs.com
www.changxinsz.com

We operate ABB, GE aereration, A-B, Honeywell, KUKA, SCHNEIDER, Bentley, TRICONEX Invensys, WOODWARD, FOXBORO, WESTINGHOUSE, and MOTOROLA MOTOROLA, KEBA, KOLLMORGEN, EMERSON, HIMA dark horse, industrial and commercial energy storage, container energy storage, household light energy storage, (peak cutting, valley filling, backup power supply) can be contacted if necessary.

Country of Origin: USA
Moq :1 piece
Packaging: new raw materials and individual packaging
Delivery time :2-3 working days
Payment method: Bank transfer, Western Union

A-B 1734-OW4

The Allen-Bradley 1734-OW4 is a digital output module belonging to the Point I/O family. It is primarily used to control external devices in Allen-Bradley’s small PLC system. The module contains four independent relay output channels, each of which can be controlled individually. These output channels are usually used to drive loads such as solenoid valves, relays, and motor starters to achieve on-off control of external devices.

Product parameters and specifications:
Model: 1734-OW4

A-B	1734-OW4 Digital output module
Function: digital output

A-B	1734-OW4 Digital output module1
Output type: 4-way SPST normally open relay
Voltage: 24V DC
Current: 2A/ channel
Response time: 20ms (ON to OFF)
Mounting method: DIN rail mounting
Features:
Independent control: Each channel can be controlled separately
Rugged: Suitable for industrial environments
Easy installation: DIN rail installation is quick and easy
Main functions:
Control external devices: Control external devices by closing or opening relay contacts.
Achieve logic control: Cooperate with PLC program to achieve complex logic control.
Expand I/O: Increase the number of PLC output points.
Application scenario:
Industrial automation: Control of motors, valves, pumps and other equipment
Machine automation: control machine start, stop, action
Process control: control heating, cooling and other processes
Note the following when selecting the 1734-OW4 module:
Load current: Ensure that the load current does not exceed the rated current of the module.
Voltage: Ensure that the load voltage is consistent with the module output voltage.
Response time: Select the appropriate response time according to the application requirements.
Environmental conditions: Check whether the operating temperature and humidity of the module meet the installation environment.