Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the image-sizes domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the uael domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra-addon domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114
1756-IB32 AB - Changxin Automation

1756-IB32 AB

1756-IB32 AB

The 1756-IB32 AB digital input module has the following features:

32 digital inputs

Input voltage range:10-30V DC

Input current:3.0 mA at 24V DC

Input delay:5 ms on/off response time

1756-IB32 AB

The 1756-IB32 AB is a digital input module manufactured by Allen-Bradley. This module is a part of the ControlLogix series of programmable logic controllers (PLCs) and is designed to provide reliable and accurate digital input to the PLC.

Product Information Content

The 1756-IB32 AB digital input module has the following features:

  • 32 digital inputs
  • Input voltage range: 10-30V DC
  • Input current: 3.0 mA at 24V DC
  • Input delay: 5 ms on/off response time

1756-IB32  AB

Parameters

The following parameters can be configured on the 1756-IB32 AB digital input module:

  • Input filter time: This parameter specifies the time delay before the input signal is processed by the module. The range is 0-32767 ms.
  • Input hysteresis: This parameter sets the hysteresis value for the input signal. The range is 0-32767 ms.
  • Input scaling: This parameter defines the scaling factor for the input signal. The range is 0-32767.
  • Input debounce time: This parameter sets the debounce time for the input signal. The range is 0-32767 ms.

1756-IB32  AB1

Conclusion

The 1756-IB32 AB digital input module is a reliable and versatile module that provides accurate digital input to the ControlLogix PLC. With its numerous parameters and features, it is a valuable addition to any automation system.

1756-IB32  AB2

Scroll to Top