Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the image-sizes domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the uael domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra-addon domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114
1407-CGCM/C AB - Changxin Automation

1407-CGCM/C AB Analog input module

1407-CGCM/C AB Analog input module

1407-CGCM/C AB

Product Details:
Country of Origin: USA
Brand:AB
Model:1407-CGCM/C

Minimum order quantity :1 item
Packaging parts: raw materials for new plant and separate packaging
Delivery time :2-3 working days
Payment: Bank transfer, Western Union

1407-CGCM/C AB

The 1407-CGCM/C AB is an analog input module of the ABB AC31 family for industrial control systems. It has 8 analog inputs and can be used to measure various process parameters.

Product description

The 1407-CGCM/ CAB has a modular design and can be combined flexibly as required. It has the following characteristics:

8 analog inputs: can be used to measure 0-10 V, 0-20 mA, 4-20 mA, 1-5 V or 2-10 V voltage or current.
±0.1% accuracy: It can meet the needs of high-precision measurement applications.
High reliability: Advanced design and manufacturing process, with high reliability.
Easy to use: with friendly operation interface, easy to use.
Product parameter

Technical parameters of 1407-CGCM/C AB are as follows:

Analog input:
Quantity: 8
Measuring range: 0-10 V, 0-20 mA, 4-20 mA, 1-5 V, 2-10 V
Accuracy: ±0.1%
Power Supply: 24 V DC
Operating temperature: -20 ℃~+60 ℃
Product specification

The dimensions and weight of 1407-CGCM/C AB are as follows:

Dimensions: 125 x 90 x 60 mm
Weight: 0.5kg
Product application

The 1407-CGCM/C AB can be used in the following applications:

1407-CGCM/C  AB  Analog input module

Industrial control: Used to measure various process parameters, such as temperature, pressure, flow, speed, etc.
Robot: Used to measure the movement and position of the robot.
Medical devices: Used to measure the parameters of medical devices.
Specific application

The 1407-CGCM/C AB can be used in the following specific applications:

Used to measure the temperature of the heating furnace.
Used to measure the pressure of the compressor.
Used to measure the flow of the flow control valve.
Used to measure the speed of the motor.
Used to measure the temperature of medical equipment.
advantage

1407-CGCM/C AB offers the following advantages:

1407-CGCM/C  AB  Analog input module1

High accuracy: Accuracy of ±0.1% can be provided.
High reliability: Advanced design and manufacturing process, with high reliability.
Easy to use: with friendly operation interface, easy to use.
Inferior position

1407-CGCM/C AB has the following disadvantages:

The price is relatively high.
Substitute product

1407-CGCM/C AB alternatives include:

Siemens SIMATIC ET 200SP analog input module
Rockwell AutomationDirect analog input module
Schneider Electric XC900 analog input module