1794-OE4 AB

1794-OE4 AB

Specifications

Operating Voltage:120/240V AC

Input Type:Analog(Voltage/Current)

Input Range:0-10V DC,0-20mA DC

Output Type:Analog(Voltage/Current)

Output Range:0-10V DC,0-20mA DC

Accuracy:+/-0.1%full scale

Isolation Voltage:250V AC

Operating Temperature:-20 to 60 degrees Celsius

Mounting Type:DIN rail

1794-OE4 AB

This document provides a detailed description of the 1794-OE4 AB module. The 1794-OE4 AB module is an analog output module that can be used with Allen-Bradley programmable controllers. It has four output channels that can be configured for voltage or current output. The module is designed for use in industrial applications and has a wide operating temperature range of -20 to 60 degrees Celsius. It is also designed to withstand high levels of shock and vibration.

The module is easy to install and configure. It can be mounted on a DIN rail and has removable terminal blocks for easy wiring. The module can be configured using the controller’s programming software. Configuration options include selecting the output type, setting the output range, and configuring diagnostic alarms.

The 1794-OE4 AB module is a reliable and versatile analog output module that is ideal for use in a variety of industrial applications. Its rugged design, wide operating temperature range, and easy installation and configuration make it a popular choice among engineers and technicians.

If you are interested in learning more about the 1794-OE4 AB module, please refer to the manufacturer’s documentation or contact your local Allen-Bradley distributor.

1794-OE4  AB

Specifications

  • Operating Voltage: 120/240V AC
  • Input Type: Analog (Voltage/Current)
  • Input Range: 0-10V DC, 0-20mA DC
  • Output Type: Analog (Voltage/Current)
  • Output Range: 0-10V DC, 0-20mA DC
  • Accuracy: +/- 0.1% full scale
  • Isolation Voltage: 250V AC
  • Operating Temperature: -20 to 60 degrees Celsius
  • Mounting Type: DIN rail

1794-OE4  AB1

Features

  • High accuracy and resolution
  • User-configurable input and output ranges
  • Built-in diagnostic and fault detection capabilities
  • Easy to install and set up
  • Compact and rugged design for harsh industrial environments
  • UL Listed and CE Certified

Parameters

  • Input Filter: Selectable 50/60 Hz
  • Output Update Time: 100 ms
  • Output Resolution: 12-bit (0.025%)
  • Input Resistance: Voltage: 1.1 Mohm; Current: 250 ohm
  • Output Load Resistance: Voltage: 10 kohm min; Current: 500 ohm max
  • Overvoltage Protection: 120% of full scale
  • Undervoltage Protection: 10% of full scale