PLC

1785-BCM AB

he AB 1785-BCM comes with the following parameters:

ControlNet Group:The ControlNet group number to which the module is assigned.

Module Name:The user-defined name of the module.

IP Address:The IP address of the module’s built-in web server.

Subnet Mask:The subnet mask of the module’s built-in web server.

Gateway:The default gateway of the module’s built-in web server.

Get A Quote
Contact Us

1785-BCM AB

The 1785-BCM AB is a ControlLogix back-up communication module manufactured by Allen Bradley. It is designed to work with ControlLogix controllers and provides a backup communication path in case of a primary communication failure. The module has an RS-232 serial port for communication and supports protocols such as DF1, DH+, and ASCII.

The 1785-BCM AB also has a battery backup that allows it to store configuration data and system information in case of a power outage. This ensures that the system can quickly resume normal operation once power is restored.

Overall, the 1785-BCM AB is a reliable and essential component for maintaining the communication and operation of ControlLogix systems.

1785-BCM  AB

Parameters

The AB 1785-BCM comes with the following parameters:

  • ControlNet Group: The ControlNet group number to which the module is assigned.
  • Module Name: The user-defined name of the module.
  • IP Address: The IP address of the module’s built-in web server.
  • Subnet Mask: The subnet mask of the module’s built-in web server.
  • Gateway: The default gateway of the module’s built-in web server.

1785-BCM  AB1

The AB 1785-BCM also supports the following modes:

  • Normal: The module operates in normal mode and provides communication between the ControlLogix chassis and the ControlNet network.
  • Forced: The module is forced into run mode to allow firmware updates or module configuration changes.

1785-BCM  AB2

Tags: ,