Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the image-sizes domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the uael domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra-addon domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /data/wwwroot/www.changxindcs.com/wp-includes/functions.php on line 6114
DEIF MTR-3F-215 Multifunctional power grid monitor - Changxin Automation

DEIF MTR-3F-215 Multifunctional power grid monitor

DEIF MTR-3F-215 Multifunctional power grid monitor

DEIF MTR-3F-215

Today’s recommended products:
LAM 839-101612-885
LAM 839-101612-887
LAM 719-101612-885
LAM 719-101612-887
Many in stock, first come first served, first-hand source, channel
Contact: Han Fangting Sales Manager
Mobile :18030042035
QQ: 748141623
Email: 748141623@qq.com
Web site :www.changxindcs.com
www.changxinsz.com

We operate ABB, GE aereration, A-B, Honeywell, KUKA, SCHNEIDER, Bentley, TRICONEX Invensys, WOODWARD, FOXBORO, WESTINGHOUSE, and MOTOROLA MOTOROLA, KEBA, KOLLMORGEN, EMERSON, HIMA dark horse, industrial and commercial energy storage, container energy storage, household light energy storage, (peak cutting, valley filling, backup power supply) can be contacted if necessary.

Country of Origin: USA
Moq :1 piece
Packaging: new raw materials and individual packaging
Delivery time :2-3 working days
Payment method: Bank transfer, Western Union

DEIF MTR-3F-215

The DEIF MTR-3F-215 module is a multifunctional power grid monitor, mainly used to monitor and control various parameters of the power system. The module integrates a variety of measurement functions to provide accurate and reliable electrical data, providing important support for the operation and maintenance of power systems.

Product name

DEIF	MTR-3F-215 Multifunctional power grid monitor
English: DEIF MTR-3F-215 Multifunctional power grid monitor
English: DEIF MTR-3F-215 Electrical Network Multi-Transducer Monitor
Product description

DEIF	MTR-3F-215 Multifunctional power grid monitor1
The MTR-3F-215 module is capable of measuring and monitoring various electrical parameters, including:

Voltage: three-phase voltage, phase voltage, zero sequence voltage, etc.
Current: three-phase current, zero sequence current, etc.
Power: active power, reactive power, apparent power, power factor, etc.
Frequency: power grid frequency.
Harmonics: Harmonic components of voltage and current.
Other: voltage unbalance, phase Angle, etc.
The module also has the following features:

Alarm function: When the power grid parameters exceed the set range, the module will send an alarm signal.
Communication function: The module supports a variety of communication protocols and can transmit measurement data to the host computer or SCADA system.
Display function: The module is equipped with LCD screen, which can display measurement data and alarm information in real time.
Product parameters and specifications
The specific parameters and specifications of the MTR-3F-215 module will vary depending on the model and configuration. In general, its main parameters include:

Measuring range: Measuring range of voltage, current, power and other parameters.
Accuracy: The accuracy of the measured data.
Sampling rate: How often data is sampled.
Communication interface: RS485,